Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Comput Assist Tomogr ; 47(1): 71-77, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36194845

RESUMEN

PURPOSE: The aim of the study is to analyze incidence and risk factors for air embolism during computed tomography (CT) fluoroscopy-guided lung biopsies using noncoaxial automatic needle. MATERIALS AND METHODS: Between February 2014 and December 2019, 204 CT fluoroscopy-guided lung biopsies (127 men; mean age, 70.6 years) using noncoaxial automatic needle under inspiratory breath holding were performed. We retrospectively evaluated the incidence of air embolism as presence of air in the systemic circulation on whole-chest CT images obtained immediately after biopsy. Risk factors of the patient, tumor and procedural factors (size, location and type of nodule, distance from the pleura, the level of the lesion relative to the left atrium, emphysema, patient position, penetration of a pulmonary vein, etc) were analyzed. RESULTS: The technical success rate was 97.1%. Air embolism was radiologically identified in 8 cases (3.92%, 7 males; size, 21.6 ± 18.2 mm; distance to pleura, 11.9 ± 14.5 mm). Two patients showed overt symptoms and the others were asymptomatic. Independent risk factors were needle penetration of the pulmonary vein ( P = 0.0478) and higher location relative to left atrium ( P = 0.0353). Size, location and type of nodule, distance from the pleura, emphysema, patient position, and other variables were not significant risk factors. As other complications, pneumothorax and alveolar hemorrhage were observed in 57.4% and 77.5%, respectively. CONCLUSIONS: In CT fluoroscopy-guided lung biopsy using the noncoaxial automatic needles, radiological incidence of air embolism was 3.92%. Given the frequency of air embolism, it is necessary to incorporate this into postprocedure imaging and clinical evaluation.


Asunto(s)
Embolia Aérea , Enfisema , Neoplasias Pulmonares , Neumotórax , Enfisema Pulmonar , Masculino , Humanos , Anciano , Embolia Aérea/diagnóstico por imagen , Embolia Aérea/epidemiología , Estudios Retrospectivos , Biopsia con Aguja/efectos adversos , Biopsia con Aguja/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Pulmón/patología , Neumotórax/diagnóstico por imagen , Neumotórax/epidemiología , Neumotórax/etiología , Biopsia Guiada por Imagen/efectos adversos , Tomografía Computarizada por Rayos X/métodos , Fluoroscopía/efectos adversos , Factores de Riesgo , Enfisema/complicaciones , Enfisema/patología , Radiografía Intervencional/métodos
4.
Cardiovasc Intervent Radiol ; 43(4): 630-635, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31832724

RESUMEN

PURPOSE: To compare the polymerization time of n-butyl cyanoacrylate (NBCA) and lipiodol mixture in a static model and a pulsating flow model simulating embolization procedure of small caliber arteries. MATERIALS AND METHODS: The polymerization time of NBCA-lipiodol mixture was measured by the morphological changes of a glue droplet in a petri dish. For the flow model, we used a 2-mm-inner-diameter polyvinyl alcohol tube connected to a pulsation pump. Bovine serum was supplied from the pump and circulated into the system at 30 ml/min and 60 bpm. A 0.64-mm-inner-diameter silicon microcatheter was inserted into this system, and then, 0.5 ml of glue was injected into the tube. The flow cessation time was defined as the time it took to stop the serum draining from the end of the tube. Six samples of 100, 66, 50, 40, 33, and 20 vol% NBCA were assessed. RESULTS: The median polymerization times for each concentration were 0.12, 3.72, 12.30, 27.41, 57.68, and 63.67 s, respectively. The median flow cessation times were 0.28, 0.78, 1.43, 3.75, 4.50, and 9.29 s, respectively. The flow cessation time was significantly shorter than the polymerization time for all samples except for 100 vol% cyanoacrylate (p < 0.05). CONCLUSION: The flow cessation time of cyanoacrylate glue was significantly shorter than the polymerization time in an in vitro experiment. The injected glue possibly stops the blood flow before the completion of polymerization in the vascular system.


Asunto(s)
Embolización Terapéutica/métodos , Enbucrilato/química , Aceite Etiodizado/química , Fantasmas de Imagen , Velocidad del Flujo Sanguíneo , Técnicas In Vitro/métodos , Polimerizacion , Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...